Product Description
Chilling circulators are used to do low temperature experiment such as chemical, biological and physical experiment in low temperature. They are ideal equipment for cooling lab equipment like rotary evaporators, glass reactors, wiped film evaporators, etc.
Features:
Closed cycle pipeline design highly prevents circulating water pollution and extends the lifetime of circulation liquid.
Multi-grade safety elements, user-friendly design.
Brand compressor, cascade refrigeration cooling technologies.
Efficient two-condensate system.
Computer-cascade temperature controller, temperature figures display, adjustable unit is 0.10℃
Use of cold technology, can guarantee the stability of temperature at low temperature.
Can set the temperature difference of compressor on/off.
Monitoring the ambient temperature, prevent temperature to be higher in the running system.
A variety of fault alarm (over temperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm).
Power on delay protection, three-level cascade system protectors.
Power on delay protection, three-level cascade system protectors.
Adopt full closed circulation design, no water vapor at low temperature and ensure the purity of cooling medium in case of ice crystals, provide a long time life of heat transfer liquid.
High-performance circulating pump, can guarantee 24 hours' continuously running a day.
Use plate cool-heat-exchanger, heat transfer efficiency is provided.
Model No |
Volume |
Temperature |
Cooling capacity |
Circulating flow |
Lift |
Voltage |
Current |
Power |
RNLB-5/30 |
5L |
-30℃~RT |
875~225W |
20 L/min |
8m |
220V |
2.8A |
470W |
RNLB-5/40 |
5L |
-40℃~RT |
1900~170W |
20 L/min |
8m |
220V |
3.7A |
900W |
RNLB-5/80 |
5L |
-80℃~RT |
2044~170W |
20 L/min |
8m |
220V |
6.5A |
1700W |
RNLB-10/30 |
7L |
-30℃~RT |
2010~650W |
20 L/min |
8m |
220V |
5.2A |
1000W |
RNLB-10/40 |
7L |
-40℃~RT |
2800~550W |
20 L/min |
8m |
220V |
5.8A |
1300W |
RNLB-10/80 |
7L |
-80℃~RT |
3690~950W |
35 L/min |
12m |
220V |
10A |
2500W |
RNLB-20/30 |
7L |
-30℃~RT |
2800~600W |
20 L/min |
8m |
220V |
6.3A |
1300W |
RNLB-20/40 |
7L |
-40℃~RT |
7300~1200W |
20 L/min |
8m |
380V |
7A |
3200W |
RNLB-20/80 |
7L |
-80℃~RT |
8760~950W |
35 L/min |
12m |
380V |
12A |
6000W |
RNLB-30/30 |
10L |
-30℃~RT |
6600`600W |
35 L/min |
12m |
220V |
11A |
2100W |
RNLB-30/40 |
10L |
-40℃~RT |
8300~900W |
35 L/min |
12m |
380V |
7A |
3200W |
RNLB-30/80 |
10L |
-80℃~RT |
10760~950W |
35 L/min |
12m |
380V |
12A |
6000W |
RNLB-50/20 |
17L |
-20℃~RT |
7300~900W |
35 L/min |
12m |
220V |
10A |
2500W |
RNLB-50/30 |
17L |
-30℃~RT |
11700~900W |
35 L/min |
12m |
380V |
8A |
4000W |
RNLB-50/40 |
17L |
-40℃~RT |
12775~650W |
35 L/min |
12m |
380V |
11A |
5500W |
RNLB-50/80 |
17L |
-80℃~RT |
15330~550W |
35 L/min |
12m |
380V |
20A |
10800W |
RNLB-100/30 |
35L |
-30℃~RT |
15750~1600W |
43 L/min |
20m |
380V |
11A |
5600W |
RNLB-100/40 |
35L |
-40℃~RT |
15750~550W |
43 L/min |
290 |
380V |
11A |
5600W |
RNLB-100/80 |
35L |
-80℃~RT |
17750~1100W |
43 L/min |
20m |
380V |
20A |
11000W |
RNLB-200/40 |
100L |
-40℃~RT |
22500~1800W |
97 L/min |
10m |
380V |
18A |
12000W |
RNLB-200/80 |
100L |
-80℃~RT |
26250~3500W |
97 L/min |
10m |
380V |
32A |
15700W |
RNLB-300/40 |
100L |
-40℃~RT |
29250~2100W |
180 L/min |
10m |
380V |
20A |
10500W |
RNLB-300/80 |
100L |
-80℃~RT |
34125~4500W |
180 L/min |
10m |
380V |
40A |
20150W |
RNLB-500/40 |
300L |
-40℃~RT |
67500~5500W |
180 L/min |
15m |
380V |
26A |
12000W |
RNLB-500/80 |
300L |
-80℃~RT |
78750~1100W |
180 L/min |
15m |
380V |
48A |
23410W |